Training Articles
Troubleshooting PAC Systems: How
to Nullify Noise
By Dave Cook, Centricut Technical Services
Director
Article originally appeared in "Welding Design & Fabrication"
November 2000
How to Nullify Noise
Symptom: The cutting machine behaves erratically during
piloting of the plasma torch: the CNC may "lock up", or the torch
carriage or beam may lose position and "run away." The machine
motion is normal in a dry run or manual operation.
Background: The high voltage spark required to create
a pilot arc in plasma systems (from 3,000 to 10,0000 VAC) creates
Radio Frequency RF electrical noise. This noise can interfere
with operation of nearby electrical equipment.
WARNING! Read all safety information
in your operations manual before operating or repairing PAC equipment.
PAC systems use high voltage and direct current (DC) electricity.
Electric shock can injure or kill!
Earth ground vs. noise ground: although used interchangeably,
these terms represent two different grounding schemes. The earth
(or power) ground uses the earth as the conductive current return
path to the lowest potential point of a power generation system.
A true earth ground, as defined by the National Electric Code,
consists of a conductive (usually copper) rod or pipe driven into
the earth to a minimum depth of eight feet. The rod should be
at least 7/8" in diameter to ensure a proper ground.
While the earth ground conducts electricity, the noise ground
diverts radio frequency RF electrical "noise" to the earth. RF
noise emanates radially from the pilot arc cable inside the lead
set. If not shielded and grounded properly, any component on the
cutting machine can act as an antenna--picking up RF from the
plasma leads and transmitting it to electronic equipment. Encoder
wires, motor wires, THC cables and CNC cables are particularly
susceptible. If these cables and devices pick up noise they may
malfunction causing erratic machine performance.
The work cable is neither an earth ground nor a noise ground,
although it is connected to the same terminal strip as the earth
and noise grounds. (See Figure 1.) The work cable is the positive
(+) lead from the PAC power supply to the workpiece. This cable
completes the circuit from the torch back to the power supply,
allowing main DC current flow during a cut. (PAC is a DC electrode
negative process DCEN with the electrode inside the torch negative
(-) and the workpiece positive (+).
Earth grounding recommendations:
- Install only one ground rod, but make it as deep as necessary
to obtain the proper resistance reading for your particular
area. Ground rods of over 200' are not uncommon in dry, rocky
ground. The more ground rods driven, the more capacitance
is added to the system. This could cause a "flashback" of
power to the cutting machine in the event of a catastrophic
electrical failure.
- Make all of the machine connections in parallel, not
series. If the earth grounds are in series, the noise
from each conductor will be transmitted to the next connection
point and then dissipated into that device. Note that in the
Star Ground setup, all connections are in parallel, which
also reduces the chances of encountering ground loops.
- Be sure to test each rod and record initial readings.
Ground rods should be tested periodically to make sure that
they are still able to function properly. If it is discovered
that the conductive properties of the ground rod has decreased
over time, a material called benonite (available from any
well drilling company) can be mixed with water and poured
down the hole of the ground. This will reestablish the connection
between the rod and earth. DO NOT USE SALT as it can
corrode any ground rod material and cause a complete grounding
failure.
- If correct readings cannot be obtained by a single ground
rod, move at least 25' from the original ground rod and
drive another. Link these two rods with 4/0 cable. Again,
test each rod and record its progress; however, there should
never be more than two ground rods for any PAC system.
Noise grounding recommendations:
- Connect a wire from the RHF (Remote High Frequency)
enclosure to either the Star Ground bus strip or to the
ground rod directly. Wire gauge should be 4 to 10 AWG
stranded copper wire.
- Run a separate wire from the machine beam, each
rail, and torch carriage to either the Star Ground bus strip
or ground rod. Again, use 4 to 10 AWG stranded copper wire.
- Use braided metal shielding to cover the torch leads.
The shielding should go from the back of the torch mounting
tube to the power supply cabinet, which is grounded. This
shielding is very important for noise control!
When noise problems present first verify the earth
ground is good and check all noise ground connections for
looseness or corrosion. PAC systems use water tables in
their process, and often the terminal strip for a Star Ground
setup is in an area that is exposed to moisture and heat.
Corrosion on these terminals may prevent good conductivity.
One loose connection may cause the cutting machine to act
possessed.